Instruction manual
Page 136 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
4.2.20.1.3
Functional circuit diagram of the signal lamps
Circuit diagram 6: Functional circuit diagram of the signal lamps
4.2.20.1.4
Defaults of the digital outlets of the REA JET HR
The function of the digital inputs and outputs is determined with the parameters in the file "I/O setti
-
ngs". In order to be able to use the signal lamp directly (without creating an I/O file) each control
device is provided with a default. The default outputs are as follows:
Outlet
Function
Color of signal lamp
1
Operational
Green
2
Malfunction
Red
3
Ink message
Yellow
Table 36: Defaults of the digital outlets of the REA JET HR
pro
2K/4K in the delivery state
4.2.21
Installation of the I/O connecting element
4.2.21.1 I/O connection to the control device (A8, A14)
The data contained in this subchapter on I/O connection, the
connection values and the corresponding connection plugs
also apply for all other I/O components.
4.2.21.1.1
Assignment of the I/O connection on the control device (A8, A14)
See under 4.2.12.1.1 on page 118.