Command reference
R&S
®
ZNB/ZNBT
1217
User Manual 1173.9163.02 ─ 62
Usage:
Setting only
Manual operation:
See
[SENSe:]CORRection:COLLect:AUTO:CKIT:PORTs:ADD
<Characterization>,
<TestPort1>, <CalUnitPort1>[, <TestPort2>]...
Extends or modifies an
existing
characterization of the active calibration unit (
COMMunicate:RDEVice:AKAL:ADDRess
).
This functionality is not available at the GUI.
Setting parameters:
<Characterization>
Location of an existing characterization (e.g. created using
[SENSe:]CORRection:COLLect:AUTO:CKIT:PORTs
–
A VNA cal kit file name
*.calkit
without path refers to a
specific cal kit file stored in the internal memory of the active cal-
ibration unit.
–
A VNA cal kit file name without path but prefixed with "SD:"
refers to a specific cal kit file stored on the SD card inserted at
the active calibration unit.
–
A VNA cal kit file name
*.calkit
with path refers to a spe-
cific cal kit file stored in an arbitrary directory on the analyzer.
<TestPort1>
Number of first test port.
<CalUnitPort1>
Number of the calibration unit port, to whom test port <Test-
Port1> is assigned.
<TestPort2>
Number of the second test port ...
Example:
Prerequisite:
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess
'MyCalU'
Sets 'MyCalU' as the active calibration unit.
SYSTem:COMMunicate:RDEVice:AKAL:PORTs? 'abc'
Queries the ports of characterization 'abc'; returns something
like '3,N 50 Ohm,MALE,4,N 50 Ohm,MALE'. In particular, cali-
bration unit ports 1 and 2 are not yet characterized.
SENSe:CORRection:COLLect:AUTO:CKIT:PORTs:ADD
'abc',1,2
Extend characterization 'abc' with test port 1 assigned to port 2
of the cal unit.
SYSTem:COMMunicate:RDEVice:AKAL:PORTs? 'abc'
Now returns something like '2,N 50 Ohm,MALE,3,N 50
Ohm,MALE,4,N 50 Ohm,MALE'.
SENSe:CORRection:COLLect:AUTO:CKIT:PORTs:ADD
'abc',1,2
Repeat characterization of test port 2, e.g. because the connec-
tion cable wasn't fastened correctly ...
Usage:
Setting only
SCPI command reference