Command reference
R&S
®
ZNB/ZNBT
940
User Manual 1173.9163.02 ─ 62
Example:
*RST; :CALC:LIM:CONT 1 GHZ, 2 GHZ
Define an upper limit line segment in the stimulus range
between 1 GHz and 2 GHz, using default response values.
CALC:LIM:STAT ON; TTL2 ON
Switch the limit check on and activate the TTL out pass 2 signal.
Manual operation:
See
7.3.1.8
CALCulate:MARKer...
The
CALCulate:MARKer...
commands control the marker functions. The com-
mands are device-specific and beyond what is specified in the SCPI subsystem
SOURce:MARKer...
.
Marker addressing
For all these commands, markers are addressed via:
1. Channel number <Chn>
The command operates on the active trace of channel <Chn>.
2. Marker number <Mk>
Selects a particular marker (ignored for reference markers).
The command operates on marker <Mk> of channel <Chn>'s active trace.
CALCulate<Chn>:MARKer<Mk>:AOFF
............................................................................ 941
CALCulate<Chn>:MARKer<Mk>:BWIDth
..........................................................................942
CALCulate:MARKer:COUPled[:STATe]
.............................................................................943
................................................................................943
CALCulate<Chn>:MARKer:DEFault:FORMat
.................................................................... 944
CALCulate<Chn>:MARKer<Mk>:DELTa[:STATe]
............................................................... 946
CALCulate<Chn>:MARKer<Mk>:EXCursion
..................................................................... 946
CALCulate<Chn>:MARKer<Mk>:REFerence:EXCursion
.................................................... 946
CALCulate<Chn>:MARKer<Mk>:EXCursion:STATe
........................................................... 946
CALCulate<Chn>:MARKer<Mk>:REFerence:EXCursion:STATe
..........................................946
CALCulate<Chn>:MARKer<Mk>:FORMat
........................................................................ 947
CALCulate<Chn>:MARKer<Mk>:REFerence:FORMat
....................................................... 947
CALCulate:MARKer:FUNCtion:BWIDth:GMCenter
............................................................ 947
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE
................................................948
CALCulate<Chn>:MARKer<Mk>:FUNCtion:CENTer
.......................................................... 948
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:CENTer
......................................... 948
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER[:RANGe]
.................................. 949
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER[:RANGe]
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:SHOW
.....................................949
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:SHOW
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt
......................................950
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP
...................................... 950
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:STARt
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:STOP
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute
........................................................ 950
SCPI command reference