Command reference
R&S
®
ZNB/ZNBT
921
User Manual 1173.9163.02 ─ 62
Manual operation:
See
CALCulate:FMODel:SFD:TOTaldiffcfg
<SFDPortConfig>
Tells the SFD tool about the port ordering of the test fixture.
Parameters:
<SFDPortConfig>
ODD | NON
ODD: odd ports are on the left and even ports are on the right
NON: ports 1 to N are on the left and ports N+1 to 2·N are on
the right
Manual operation:
See
CALCulate:FMODel... (other)
........................................................................................ 921
CALCulate:FMODel:DIRectory:DEFault
............................................................................921
CALCulate:FMODel:DIRectory:DEFault:CLEar
..................................................................921
..........................................................................................922
CALCulate:FMODel:DIRectory
<String>
Defines the common working directory of the ISD, SFD and EZD fixture modeling tools.
Parameters:
<String>
Directory path, either absolute or relative to the current directory
(
Manual operation:
See
CALCulate:FMODel:DIRectory:DEFault
Resets the common working directory of the ISD, SFD, and EZD tool to its default
C:\Users\Public\Documents\Rohde-Schwarz\Vna\Embedding
.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Usage:
Event
Manual operation:
See
CALCulate:FMODel:DIRectory:DEFault:CLEar
Deletes all files in the common default working directory of the of the ISD, SFD, and
EZD tool (
C:\Users\Public\Documents\Rohde-Schwarz\Vna\Embedding
).
Usage:
Event
Manual operation:
See