UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1
Page: 357/970
target devices must have the ping utility enabled and running on top of TCP/IP. The switch can
be pinged from any IP workstation with which the switch is connected through the default VLAN
(VLAN 1), as long as there is a physical path between the switch and the workstation. The
terminal interface sends, three pings to the target station.
Syntax
ping <host>
<host> - A host name or an IP address.
Default Setting
None
Command Mode
Privileged Exec
Ping on changing parameter value
Syntax
ping <host> count <0-20000000> [size <32-512>]
ping <host> size <32-512> [count <0-20000000>]
<ipaddr> - an IP address.
<0-20000000> - number of pings (Range: 0 - 20000000). Note that 0 means infinite.
<size> - packet size (Range: 32 - 512).
Default Setting
Count = 5
Size = 32
Command Mode
Privileged Exec
6.17.7.2 ping ipv6 <ipv6-address>