UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1
Page: 719/970
11.2.2.10.3.
Configuring each Port GARP Configuration Page
Note: It can take up to 10 seconds for GARP configuration changes to take effect.
Selection Criteria
Slot/Port - Select the physical interface for which data is to be displayed or configured. It
is possible to set the parameters for all ports by selecting 'All'.
Configurable Data
Port GVRP Mode - Choose the GARP VLAN Registration Protocol administrative mode
for the port by selecting enable or disable from the pull down menu. If you select disable,
the protocol will not be active and the Join Time, Leave Time, and Leave All Time will have
no effect. The factory default is disabled.
Port GMRP Mode - Choose the GARP Multicast Registration Protocol administrative
mode for the port by selecting enable or disable from the pull down menu. If you select
disable, the protocol will not be active, and Join Time, Leave Time, and Leave All Time
have no effect. The factory default is disabled.
Join Time (centiseconds) - Specify the time between the transmission of GARP PDUs
registering (or re-registering) membership for a VLAN or multicast group in centiseconds.
Enter a number between 10 and 100 (0.1 to 1.0 seconds). The factory default is 20
centiseconds (0.2 seconds). An instance of this timer exists for each GARP participant for
each port.
Leave Time (centiseconds) - Specify the time to wait after receiving an unregister
request for a VLAN or multicast group before deleting the associated entry, in
centiseconds. This allows time for another station to assert registration for the same
attribute in order to maintain uninterrupted service. Enter a number between 20 and 600
(0.2 to 6.0 seconds). The factory default is 60 centiseconds (0.6 seconds). An instance of
this timer exists for each GARP participant for each port.
Leave All Time (centiseconds) - The Leave All Time controls how frequently LeaveAll
PDUs are generated. A LeaveAll PDU indicates that all registrations will shortly be
deregistered. Participants will need to rejoin in order to maintain registration. The Leave All
Period Timer is set to a random value in the range of LeaveAllTime to 1.5*LeaveAllTime.
The timer is specified in centiseconds. Enter a number between 200 and 6000 (2 to 60
seconds). The factory default is 1000 centiseconds (10 seconds). An instance of this timer
exists for each GARP participant for each port.
Command Buttons