AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 334 of 485
Command Syntax
[SOURce:]INTHarmonic:PHASe#
Description
This command sets the interharmonic voltage phase angle with
respect to the phase A interharmonic fundamental for the selected
phase (2 = B, 3 = C) or for both phases if the phase selection is
omitted in degrees.
Parameters
Phase
Parameter Format
<nr2>
Example
INTH:PHAS2 45.00
Query Format
[SOURce:]INTHarmonic:PHASe?
Description
Query format returns the interharmonic voltage phase angle with
respect to the phase A setting.
Returned Data Format
<nr2>
Query Example
INTH:PHAS2?
45.0000
Command Syntax
[SOURce:]INTHarmonic:PHASe#:DEFault
Description
The default interharmonic voltage phase angle for each phase or all
phases can be selected using the following command: Factory default
is 0.000° for phase A, 120.000° for phase B and 240.000° for phase C.
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:PHAS2:DEF 90
Query Format
[SOURce:]INTHarmonic:PHASe#:DEFault?
Description
Query format returns the interharmonic default voltage phase angle
setting.
Returned Data Format
<nr2>
Query Example
INTH:PHAS:DEF?
0.0000, 120.0000, 240.0000
Query Format
[SOURce:]INTHarmonic:PHASe#:MAXimum?
Description
Returns the upper interharmonic voltage phase angle setting range
for each phase or all phases. The Maximum set values in 360.000°.
Returned Data Format
<nr2>
Query Example
INTH:PHAS:MAX?
360.0000
Query Format
[SOURce:]INTHarmonic:PHASe#:MINimum?
Description
Returns the lower interharmonic voltage phase angle setting range
for each phase or all phases. Minimum set value is 0.000°.
Returned Data Format
<nr2>
Query Example
INTH:PHAS:MIN?
0.0000