AFX SERIES® OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 46 of 485
4.15.2
Technical Specifications 400V Range
AC OUTPUT
Voltage
AC Only Range
0 - 400 V L-N rms / 0 - 692V L-L rms
Programming Resolution
0.01 V
Accuracy
± (0.25% + 0.25* f (kHz)) F.S.
Constant Power Range
From 40% to 100% of Voltage Range:
160Vac L-N to 400Vac L-N
External Voltage Sense
Automatically scaled for 400Vac Range
Frequency
Range
45.00 – 1000.0 Hz
Linear voltage derating from 45Hz to 15Hz.
Linear current derating from 1000Hz to 1200Hz.
Extended Frequency Ranges are not available on T Option AC range
Programming Resolution
1
0.01 Hz
Accuracy
± 0.01%
Current
2
Range
Available RMS Current per phase is scaled by transformer ratio. E.g. for 3150AFX,
max current at 400Vac L-N is (41.7 * ¾) = 31.27Arms in 3 Phase mode
Current Overload
Available 30% Current overload for up to 2.0 seconds when enabled.
Note 1:
FREQUENCY PROGRAM RESOLUTION FOR EXPORT MODELS (-4LE, -2LE -4AGE, -2AGE):
Per U.S.A. Bureau of Industry and Security, ECCN 3A225, frequency control is limited to no better than 0.2% at
frequencies of 600 Hz. or more for unrestricted export products. To meet that requirement, frequency
programming in all AFX-xx
E
models has three resolution ranges, which round the frequency to the nearest
increment, as defined in the table below.
Frequency Resolution for Export Models
Range
Resolution
15.00 - 99.99 Hz
0.01 Hz
100-599.9 Hz
0.1 Hz
600 - 999 Hz
2.0 Hz
1000 - 1200 Hz
5.0 Hz
Note 2:
Refer to AC Mode Voltage / Current rating charts Figure 4-14 and
Error! Reference source not found.
on
following pages.
Содержание AFX Series
Страница 484: ......