8.7.13
IEC413 Option Interharmonics Commands
The following SCPI commands apply only to AFX models with the -413 Option installed. The
presence of this option can be checked using the *IDN? Query to check for the letter “C” in the AXF
Model number. Examples: 3150AFX-4AG
C
”. See section 4.16 on page 48 for more details.
Command Syntax
[SOURce:]INTHarmonic:FREQuency
Description
Sets the frequency of the interharmonic voltage component for all
phases. The query format returns the active setting
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:FREQ 470
Query Format
[SOURce:]INTHarmonic:FREQuency?
Description
Query format returns theinterharmonic frequency setting.
Returned Data Format
<nr2>
Query Example
INTH:FREQ?
470.0000
Command Syntax
[SOURce:]INTHarmonic:FREQuency:DEFault
Description
Sets the default frequency of theinter harmonic voltage component
for all phases. The factory default setting is 1800 Hz.
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:FREQ:DEF 90
Query Format
[SOURce:]INTHarmonic:FREQuency:DEFault?
Description
Query format returns the interharmonic frequency setting.
Returned Data Format
<nr2>
Query Example
INTH:FREQ:DEF?
90.0000
Query Format
[SOURce:]INTHarmonic:FREQuency:MAXimum?
Description
Returns the maximum value for the interharmonic frequency setting
which is 10,000 Hz..
Returned Data Format
<nr2>
Query Example
INTH:FREQ:MAX?
10000.0000
Query Format
[SOURce:]INTHarmonic:FREQuency:MINimum?
Description
Returns the minimum value for the interharmonic frequency setting
which is 15 Hz..
Returned Data Format
<nr2>
Query Example
INTH:FREQ:MIN?
15.0000