AFX SERIES® OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 442 of 485
Grouping
Controls
Trigger Input:
STATUS
[ ON | OFF ] Enabled or disabled
IMMEDIATE
[ ON | OFF ] Ignore phase update
setting if ON
AUTORUN
[ ON | OFF ] No RUN command
required if ON
––Strobe Output:
TRANSIENT
ON = Strobe output on transient
start
OUTPUT STATE
ON = Strobe output on relay close
SOURCE
ON = Strobe output on any program
parameter change
External Sync:
STATUS
Display SYNC Status
EXTERNAL SYNC [ ON | OFF ]
SYNC SOURCE
Select Sync source
Available sources are:
- External sync input on I/O
connector
- LINE (AC input to power source)
PHASE SHIFT
Offset Phase A angle
SPEED
1.00 ~ 10.00
RANGE
0.10 ~ 500 Hz
EXTERNAL SYNC [ ON | OFF ]
Remote Controls:
DISABLED
No remote output control
REMOTE INHIBIT Contact closure needed to close
output relay
REMOTE ENABLE Contact closure or front panel can
control output relay
Содержание AFX Series
Страница 484: ......