AFX SERIES® OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 116 of 485
SOFT KEY
Description
Peak
Current (SK3)
Displays the Peak Current protection screen. This protection function
is separate from the RMS current limit function. By setting the peak
current protection mode, the maximum peak current is limited by the
power source to the programmed level. This is done on a cycle by
cycle basis. Note that a minimum setting applies as described in
section 6.4.9, next page.
The level can be set using the shuttle or key pad. To enable or disable
this function, scroll to the “Enable peak current protection” check box
and press the shuttle to toggle on or off.
Waveform
(SK4)
Displays the Waveform selection screen. This function allows the
active waveform shape to be changed. Available waveform selections
are:
Sinewave, Clipped Sinewave 1% THD, Clipped Sinewave 2% THD,
Clipped Sinewave 5% THD, Clipped Sinewave 10% THD, Square and
Triangle.
Select waveform using the shuttle. Each waveform can be previewed.
With the desired waveform displayed, press the “Apply” soft key to
confirm. This will take you back to the PROGRAM screen.
Apply All (SK5)
The “Apply all” soft key is used to confirm all presets made to
program parameters in the PROGRAM screen. When pressed, all
newly set values are applied to the output and the parameter
background colors revert back to white.
Table 6-4: PROGRAM screen soft keys
Содержание AFX Series
Страница 484: ......