Query Syntax
[SOURce:]STEP:DWELL:MAXimum?
Description
This command returns highest permissible set value for the STEP
dwell time setting.
Returned Data Format
<nr2>
Query Example
STEP:DWELL:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
Query Syntax
[SOURce:]STEP:DWELL:DEFault?
Description
This command returns default set value for the STEP dwell time
setting.
Returned Data Format
<nr2>
Query Example
STEP:DWELL:DEF?
0.0998
Command Syntax
[SOURce:]STEP:RAMP <time>, <opt>
Description
This command sets the ramp time of the step in seconds
Minimum time set value allowed is 0.0002 sec. (0.2 msec)
Parameters
Time in seconds, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
STEP:MODE:RAMP 5, SAT
Query Format
[SOURce:]STEP:RAMP?
Returned Data Format
<nr2>
Query Example
STEP:RAMP?
5.0000, SAT
Query Syntax
[SOURce:]STEP:RAMP:MINimum?
Description
This command returns lowest permissible set value for the STEP ramp
time setting.
Returned Data Format
<nr2>
Query Example
STEP:RAMP:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
Query Syntax
[SOURce:]STEP:RAMP:MAXimum?
Description
This command returns highest permissible set value for the STEP
ramp time setting.
Returned Data Format
<nr2>
Query Example
STEP:RAMP:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings