AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 465 of 485
Error Source
Code
Category Error Message
Possible Cause
Resolution
Front panel
Error
172
Error
Command not allowed
during power stage
firmware update.
Notification. Firmware
update for Power Stage in
progress. Command not
allowed during this time.
Wait for all firmware
updates to be completed
Front panel
Error
173
Error
Cannot change Current
RMS Overload mode with
output enable.
Setting conflict. Current
RMS overload mode can
only be enabled with
output OFF
Turn output OFF, then
enable Current RMS
Overload mode
Front panel
Error
174
Error
Strobe feature not
available in this model.
Function Strobe Output
not supported. Feature
not available
Requires AUX I/O board
Front panel
Error
175
Error
Feature not available in
this model.
Feature not available.
Requires AUX I/O board
Front panel
Error
176
Error
Set points cannot be
changed while transient
program is running.
Setting conflict.
Attempting to change
setting while transient
execution is in progress
Abort Transient Run or
wait for transient
execution to complete
Front panel
Error
180
Error
Unknown processor type
detected. Run unit
discovery to recover.
Auxiliary unit not
recognized. One of more
auxiliary units were not
recognized during
discovery
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
181
Error
Undiscovered node
detected. Run unit
discovery to recover.
An inconsistency was
detected in the unit
internal communication
network.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Front panel
Error
182
Error
Incorrect parallel unit
count
Setting conflict. Auxiliary
unit count does not
match expected count
setting
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover or adjust
expected count to match
actual no of units
Front panel
Error
183
Error
Invalid processor type
Auxiliary unit not
recognized
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
184
Error
Daisy chain invalid type
Error during discovery
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
185
Error
Undiscovered controller
node was detected.
An inconsistency was
detected in the power
source's internal
communication network.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Front panel
Error
186
Error
No master front panel
was detected.
Error during discovery.
No Master found
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Front panel
Error
187
Error
More than enabled
master controller is was
Error during discovery.
Too many masters
Check all parallel cables
between units. Run
parallel unit discovery
Содержание AFX Series
Страница 484: ......