AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 212 of 485
•
IMMEDIATE
[ ON | OFF ] Ignore phase update setting if ON
•
AUTORUN
[ ON | OFF ] No RUN command required if ON
7.3.13.9
Strobe Output
The Strobe Output is used to synchronize or trigger external equipment to an event
occurring on the AC power source.
Available settings are:
•
TRANSIENT
ON = Strobe output on transient start
•
OUTPUT STATE
ON = Strobe output on relay close
•
SOURCE
ON = Strobe output on any program parameter change
7.3.13.10
Remote Control
The remote control input is used to control operation of the output relay.
Available settings are:
•
DISABLED
No remote output control
•
REMOTE INHIBIT
Contact closure needed to close output relay
•
REMOTE ENABLE
Contact closure or front panel can control output relay
See Section 6.8.5.6.
Содержание AFX Series
Страница 484: ......