AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 276 of 485
8.7.5
Phase Programming Commands
Command Syntax
[SOURce:]PHASe#
Description
This command programs the phase angle for the selected phase. A
phase reference (#) must be specified.
Note
that unless external sync mode is used, the A phase (# = 1)
cannot be programmed is fixed at 0 degrees.
Parameters
0.0 – 359.9
Parameter Format
<nr2>
Example
PHAS2 122.5
Query Format
[SOURce:]PHASe#?
Returned Data Format
<nr2>
Query Example
PHAS2?
122.5
Command Syntax
[SOURce:]PHASe#:SLEW
Description
This command sets slew rate for the phase angle for the selected
phase. A phase reference (#) must be specified.
Note
that unless external sync mode is used, the A phase (# = 1) slew
rate cannot be programmed is fixed at 0 degrees.
Parameters
0.01 – 359.91
Parameter Format
<nr2>
Example
PHAS3:SLEW 10.25
Query Format
[SOURce:]PHASe#:SLEW?
Returned Data Format
<nr2>
Query Example
PHAS3:SLEW?
10.2500
Command Syntax
[SOURce:]PHASe:ROTation <b>
Description
This command sets default phase rotation at power on. Available
settings are POSITIVE (1) or NEGATIVE (0). This setting effectively
swaps phases B and C and may be used to set the required phase
rotation for AC motors.
Parameters
[ 0 | NEGative | 1 | POSitive]
0 = NEGATIVE
1 = POSITIVE
Parameter Format
<b>
Example
PHAS:ROT POS
Query Format
[SOURce:]PHASe:ROTation?
Returned Data Format
<b>
Query Example
PHAS:ROT?
1
Содержание AFX Series