AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 462 of 485
Error Source
Code
Category Error Message
Possible Cause
Resolution
Front panel
Error
107
Error
Redundant segments
were combined.
Optimization. Segment
data received contained
redundant segments
which were removed
Not needed
Front panel
Error
108
Error
Redundant steps were
combined.
Optimization. List Step
data received contained
redundant steps which
were removed
Not needed
Front panel
Error
109
Error
Transient step mode not
available on UPC
compatible mode.
Setting conflict. Step
mode only supported in
AFX mode.
Switch to AFX mode or
use Segments
Front panel
Error
110
Error
System is about to
reboot.
Warning, Reboot
imminent
Wait
Front panel
Error
111
Error
Cannot reboot system.
Soft reboot failed. Front
panel could not reboot
itself.
Try recycling power. If
error persists, contact
customer service
Front panel
Error
115
Error
Unable to renew the
DHCP lease. Changing to
Auto-IP mode.
LAN Error. IP address
lease from DHCP expired
Renew IP lease of use
Auto IP mode
Front panel
Error
116
Error
Failed starting firmware
update.
Firmware Update Error.
Unable to start firmware
update
Check for correct
firmware image file and
version.
Front panel
Error
117
Error
Unable to execute this
action with output
enable.
Setting conflict.
Requested action not
possible with output ON
Turn output OFF
Front panel
Error
118
Error
Frequency set point
cannot change due to
waveform saturation.
Setting conflict. In
extended voltage range,
frequency range is
restricted. Max peak
voltage is reduced
outside this range and if
there is a DC offset
programmed, the peak of
the voltage exceeds the
max. limit.
Reduce programmed
RMS and/or DC value.
Front panel
Error
119
Error
Frequency set point
cannot change due to
user limit.
Setting conflict.
Frequency set point
outside User Limits
Change User Limits or
frequency setting
Front panel
Error
120
Error
Frequency not allowed in
"DC mode".
Setting conflict. No
frequency setting applies
in DC mode
Change to AC or AC+DC
mode
Front panel
Error
121
Error
Waveform set point
cannot change due to
waveform saturation.
Setting conflict. The crest
factor of the waveform
selected would result in a
peak voltage that exceeds
the max peak voltage
supported. Or combined
AC peak + DC
programmed exceeds
max peak voltage
Reduce waveform crest
factor ratio or reduce
programmed RMS and/or
DC value.
Front panel
Error
122
Error
Cannot load program.
Run PROG:CHECK? for
more information.
Setting conflict
Use PROG:CHECK?
Command to query
conflict details
Front panel
Error
124
Error
LAN interface not
available.
LAN Error. No LAN
connection
Check connection to LAN
Front panel
Error
125
Error
Remote inhibit cannot be
disabled in this model.
Remote Inhibit always
enabled. Unit was bought
Connect Remote Inhibit
input as needed.