AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 222 of 485
Query Format
MEASure:CURRent:PEAK#:MINimum:HOLD?
Description
Returns the lowest measured peak hold current value for the selected
phase #. If no phase number is specified, returns the reading for all
phases. This reading accumulates the lowest recorded absolute peak
hold current until reset using the MEASure:CURRent:PEAK#:RESet
command.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK:MIN:HOLD?
1.0001, 0.8451, 0.4871
Query Format
MEASure:CURRent:PEAK#:MAXimum?
Description
Returns the highest measured peak current value for the selected
phase #. If no phase number is specified, returns the reading for all
phases.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK:MAX?
45.5845, 47.3213, 48,2234
Query Format
MEASure:CURRent:PEAK#:MAXimum:HOLD?
Description
Returns the highest measured peak hold current value for the
selected phase #. If no phase number is specified, returns the reading
for all phases. This reading accumulates the highest recorded
absolute peak hold current until reset using the
MEASure:CURRent:PEAK#:RESet command.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK:MAX:HOLD?
58.5845, 57.3213, 58,2234
Command Syntax
MEASure:CURRent:PEAK#:RESet
Description
This command resets all peak hold current readings for the selected
phase # to zero. If no phase number is specified, returns the reading
for all phases.to zero.
Parameters
None
Parameter Format
n/a
Example
MEAS:CURR:PEAK1:RES
Query Format
MEASure:CURRent:CREST#?
Description
Returns the measured current crest factor for the selected phase #. If
no phase number is specified, returns the reading for all phases.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:CREST1?
2.1544