AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 271 of 485
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MAXimum?
Description
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MAX?
254.946
Query Format
[SOURce:]VOLTage:DC#:LIMit:SATuration:MINimum?
Description
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage:DC#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:DC3:LIM:SAT:MIN?
-254.946
Command Syntax
[SOURce:]VOLTage:EXTend
Description
This command grants access to a higher voltage range extension
mode. When enabled, AC voltage settings up to 333V L-N are
supported.
Parameters
[ 0 | OFF | 1 | 2 ]
0 = Off, 312Vac max.
1 = 320Vac max
2 = 333Vac max
Parameter Format
<bool>
Example
VOLT:EXT 1
Query Format
[SOURce:]VOLTage:EXTend?
Returned Data Format
<nr1>
Query Example
VOLT:EXT?
1