05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
05
Adjustmen
t mode
Process
Developer Automatic adjustment
of auto-toner sensor
2000
Fuser heater ON
-
-
As the value increases, the sensor output increases
correspondingly. The value starts changing approx. 2
minutes after this adjustment was started and is
automatically set in the range of 2.35 to 2.45 V.
* Selection is disable when developer unit is not
installed.
17
Yes
05
Adjustmen
t mode
Process
Developer Correction of auto-
toner sensor
2001
Fuser heater ON
141
0~255
M
Corrects the control value of the auto-toner sensor
setup in 05-2000.
* Selection is disable when developer unit is not
installed.
3
Yes
05
Adjustmen
t mode
Process
Developer
2020
Developer bias DC
output adjustment
141
0~255
M
As the value increases, the transformer output
increases correspondingly. Remove the developer unit
and install the adjustment jig to make adjustment.
3
Yes
05
Adjustmen
t mode
Process
Charger
2040
Main charger grid bias
output adjustment
Refer to
content
s
0~255
M
As the value increases, the transformer output
increases correspondingly. Remove the developer unit
and install the adjustment jig to make adjustment.
<Default value>
95
3
05
Adjustmen
t mode
Process
Transfer
2052
Transfer transformer
DC output adjustment
(C)
Refer to
content
s
0~255
M
As the value increases, the transformer output
increases correspondingly. Remove the developer unit
and install the adjustment jig to make adjustment.
<Default value>
117
3
05
Adjustmen
t mode
Process
Separation
2078
Separation
transformer DC output
adjustment (C)
52
0~255
M
As the value increases, the transformer output
increases correspondingly. Remove the developer unit
and install the adjustment jig to make adjustment.
3
05
Adjustmen
t mode
Process
Transfer
Transfer cleaning bias
adjustment
2083
Positive
Refer to
content
s
0~255
M
When the high-voltage transformer is replaced, the
transfer cleaning bias needs to be adjusted with this
code. The larger the setting value is, the higher the
value of the current (more positive) is. This causes a
reduction in the toner adhering to the transfer roller and
an improvement in the cleaning performance. Perform
this adjustment after the process units (cleaner and
developer unit) have been removed. When the high-
voltage transformer is replaced, adjusting with the
following codes needs to be performed in addition to
this adjustment.
05-2020, 05-2040, 05-2052, 05-2078
<Default value>
96
3
Yes
1
Содержание ES9160
Страница 12: ......
Страница 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Страница 114: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved OUTLINE OF THE MACHINE 3 76...
Страница 252: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 4 138...
Страница 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Страница 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Страница 916: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 8 4 Turn the power OFF...
Страница 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Страница 922: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 13 2...
Страница 1086: ......
Страница 1087: ......