![Oki ES9160 Скачать руководство пользователя страница 351](http://html1.mh-extra.com/html/oki/es9160/es9160_maintenance-manual_4506366351.webp)
6
© 2012 OKI DATA CORPORATION All rights reserved
ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT
6 - 43
6.8
Adjustment of High-Voltage Transformer
When replacing the high-voltage transformer, you must check each output adjustment of the main
charger bias, developer bias, transfer bias, transfer cleaning bias (positive), transfer cleaning bias
(negative) and separation bias.
6.8.1
Adjustment
[ 1 ] Preparation
Items to check
Developer Bias
Main Charger
Transfer Bias,
Transfer Cleaning
Bias(positive),
Transfer Cleaning
Bias(negative)
Separation
Charger
Process Unit
Take the process unit out of the equipment, an then install the high-voltage transformer
jig to the unit.
High-Voltage
Transformer Jig
Install the high-voltage transformer jig in the equipment.
Notes:
Connect the green cable of the high-voltage transformer jig to ground on the
equipment frame.
P. 6-44 "[A] Installation of the high-voltage transformer jig".
Digital
Tester
(+) terminal
Connect with the
black cable (thick
line) of the high-
voltage
transformer jig.
Connect with the
red cable (thick
line) of the high-
voltage
transformer jig.
Connect with the red
cable (thin line) of the
high-voltage
transformer jig.
Connect with the
gray cable of the
high-voltage
transformer jig.
(–) terminal
Connect with the black cable (thin line) of the high-voltage transformer jig.
Function
switch
DC
Full-scale
(range)
1000 V
20 V
Remarks
Use a digital tester with an input resistance of 10 M
Ω
(RMS value) or higher.
How to turn ON
the power
Attach the door switch jig and start with the adjustment mode [05] while the front cover
opened.
Note
Connection for
developer bias
adjustment"
Содержание ES9160
Страница 12: ......
Страница 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Страница 114: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved OUTLINE OF THE MACHINE 3 76...
Страница 252: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 4 138...
Страница 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Страница 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Страница 916: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 8 4 Turn the power OFF...
Страница 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Страница 922: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 13 2...
Страница 1086: ......
Страница 1087: ......