ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT
6 - 3
(5)
After a short time, the value B becomes stable and the display changes as follows.
Fig.6-5
(6)
Check if the value B is within the range of 234 to 246 (the output voltage range of the auto-toner
sensor is 2.34 V to 2.46 V).
(7)
If the value B is not within the range of 234 to 246, press the Up or Down button to adjust the
value manually.
Notes:
The relation between the button and the values A and B is as follows.
(8)
Press the [OK] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig.6-6
(9)
Turn the power OFF.
(10) Install the toner cartridge.
Button to be pressed
Value A
Value B
Up
Increased
Increased
Down
Decreased
Decreased
240%
128
2000
ADJUSTMENT MODE
A3
150
A
B
[OK]
or
[INTERRUPT]
100%
TEST MODE
A3
A
Содержание ES9160
Страница 12: ......
Страница 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Страница 114: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved OUTLINE OF THE MACHINE 3 76...
Страница 252: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved DISASSEMBLY AND REPLACEMENT 4 138...
Страница 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Страница 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Страница 916: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 8 4 Turn the power OFF...
Страница 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Страница 922: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 13 2...
Страница 1086: ......
Страница 1087: ......