BA-982018-AIR FALCON-EN07 | www.ochsner.com 79
TEMPERATURE APPLICATION: LOW / CLIMATIC CON-
DITIONS: COLDER
AIR FALCON 212 C11A
M1-5
AIR FALCON 212 C11B
M1-5
Combination heater: DHW heating energy efficiency [ηwh]
%
-
-
TEMPERATURE APPLICATION: MEDIUM / CLIMATIC
CONDITIONS: COLDER
AIR FALCON 212 C11A
M1-5
AIR FALCON 212 C11B
M1-5
Nominal heating output [P rated] (for heating appliances and combination
heaters with heat pump, the nominal heating output P rated is equal to the
design load in heating mode Pdesignh)
kW
6
6
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=-7°C /
Indoor air temperature=20°C
kW
3.82
3.82
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=+2°C /
Indoor air temperature=20°C
kW
2.25
2.25
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=+7°C /
Indoor air temperature=20°C
kW
2.36
2.36
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=+12°C /
Indoor air temperature=20°C
kW
2.65
2.65
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=Tbiv /
Indoor air temperature=20°C
kW
4.35
4.35
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=TOL /
Indoor air temperature=20°C
kW
2.60
2.60
Specified output for partial load [Pdh]: Outdoor air temperature [Tj]=-15°C (if
TOL is less than -20°C) / Indoor air temperature=20°C
kW
4.35
4.35
Bivalent temperature [Tbiv]
°C
-15
-15
Power consumption in OFF state [POFF]
kW
0.013
0.013
Power consumption in thermostat-OFF state [PTO]
kW
0.013
0.013
Power consumption in standby [PSB]
kW
0.013
0.013
Power consumption in operation with crankcase heating [PCK]
kW
0.000
0.000
Output control
Variable
Variable
Indoor sound power level [LWA]
dB(A)
27
27
Outdoor sound power level [LWA]
dB(A)
60
60
Annual energy consumption [QHE]
kWh
6,511
6,511
Combination heater: Specified load profile
-
-
Combination heater: Daily power consumption [Qelec]
kWh
-
-
Seasonal central heating energy efficiency [ηs]
%
87.9
87.9
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=-7°C /
Indoor air temperature=20°C
1.87
1.87
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=+2°C /
Indoor air temperature=20°C
2.17
2.17
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=+7°C /
Indoor air temperature=20°C
4.72
4.72
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=+12°C /
Indoor air temperature=20°C
6.72
6.72
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=Tbiv /
Indoor air temperature=20°C
1.17
1.17
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=TOL /
Indoor air temperature=20°C
1.11
1.11
Specified COP for partial load [COPd]: Outdoor air temperature [Tj]=-15°C (if
TOL is less than -20°C) / Indoor air temperature=20°C
1.17
1.17
Operating limit temperature [TOL]
°C
-22
-22
Limit for heating water operating temperature [WTOL]
°C
60
60
Auxiliary heating appliance: Nominal heating output [Psup] (For heating appli-
ances and combination heaters with heat pump, the nominal heating output of
an auxiliary heating appliance Psup is equal to the additional heating output
sup(Tj).)
kW
3.4
3.4
Auxiliary heating appliance: Type of energy input
Electric
Electric
Nominal air flow rate, outdoors
m³/h
3,960
3,960
Combination heater: DHW heating energy efficiency [ηwh]
%
-
-
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...