OTS_EN | www.ochsner.com 19
Heating circuit
Note
Any settings made in test mode have no influence
whatsoever on your heat pump. The text “This con-
figuration is not licensed for end users” indicates
the test mode.
10.3.1 Setting up test mode
»
Open the “App management”.
»
Open the menu.
1 Menu
»
Select “Test app”.
»
Assign a user name.
11. Heating circuit
The “heating circuit” function controls the room tempera-
ture of a heating zone in heating mode and cooling mode.
The room temperature can be controlled with weather com-
pensation via a heating and cooling curve when heating
and cooling. In addition, the temperature can be controlled
with room temperature compensation if this is fitted.
11.1 Setting the room temperature
The current “Target room temperature” can be adjusted
directly on the main screen of the respective heating circuit.
»
Open the main screen of the heating circuit for which
you want to change the temperature.
»
Press the plus or minus button to adjust the “Target
room temperature”.
1 Plus/minus button
You can set one or two target values via the main screen.
(See page 20, Operating program)
Note
A change in the target room temperature automat-
ically results in a shift of the heating curve and
cooling curve. (See page 23, Weather-compen-
Note
Due to the inertia of the heating system, the effect
of changes to the room temperature settings is al-
ways delayed.
»
Perform only one adjustment per day.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...