OTS_ZSM_EN | www.ochsner.com 73
Function expansion through auxiliary modules
»
Return to the main screen.
Note
The parameters will only be displayed if the DHW
circulation pump is in the “Return temperature” op-
erating program.
33.2 Pool heating system
To be able to use this function, you need auxiliary module
A or B.
Note
The pool heating system is solely intended to ex-
tend the swimming season.
We recommend using the pool heating system on-
ly during the bathing season. Outside the bathing
season, it may not be possible to meet the build-
ing‘s heat demand.
Note
The pool heating system cannot be used for cool-
ing.
33.2.1 Operating program
Operating program
Description
Off
The pool heating system is switched off.
Automatic
The pool heating system switches to auto-
matic mode. The heat demand is made via
an external signal, e.g. a pool control. De-
pending on the requirements of this pool
control and the current operating status of
the heat pump, the pool heating system is
automatically switched on and off.
Setting the operating program
»
Open the menu.
»
Select “Pool”.
»
Select “Operating program”.
»
Make the required settings.
»
Return to the main screen.
33.2.2 Parameters
Parameters
Description
Unit
Pool flow tem-
perature
A flow temperature can be set for the
pool heating system. This should be 10 K
higher than the required pool tempera-
ture.
°C
Setting parameters
»
Open the menu.
»
Select “Pool”.
»
Select “Settings”.
»
Make the required settings.
»
Return to the main screen.
33.2.3 Operating data
In this submenu, you can view the individual data of the
pool heating system. The values in this menu cannot be
changed.
Description
Unit
Pool operating
status
The operating status of the pool heating
system is displayed here.
-
Operating
program
switched off
Pool heating is switched off via the op-
erating program “OFF”.
Heating mode The pool heating system is in automatic
mode. There is a heat demand.
Standby
The pool heating system is in automatic
mode. There is no heat demand.
Defrost
The heat pump is in defrosting mode.
The pool charging pump is switched off.
Emergen-
cy mode
switched off
The heat pump is in emergency mode.
The pool heating system is switched
off. In emergency mode, the pool heat-
ing system cannot be switched on.
System temper-
ature
In systems with a buffer tank, the buffer
tank temperature is shown here. In
systems with a bypass, the flow tem-
perature downstream of the bypass is
shown here.
°C
Heat pump outlet
temperature
The temperature of the heating water at
the heat pump outlet is shown here.
°C
Viewing operating data
»
Open the menu.
»
Select “Pool”.
»
Select “Operating data”.
33.2.4 Relay test
You must be in expert mode to use this function.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...