22
www.ochsner.com | OTS_EN
Heating circuit
Normal mode
Parameters
Description
Unit
Target room
temperature
standard cool-
ing
In cooling mode, the temperature is regu-
lated to the target value set here.
°C
Reduced
Parameters
Description
Unit
Target room
temperature
reduced cool-
ing
In cooling mode, the temperature is regu-
lated to the target value set here.
°C
11.3.3 Setting target values
The target room temperatures for the selected operating
program can be adjusted directly on the main screen of
the respective heating circuit. (See page 19, Setting the
If you want to change the target value of a different oper
-
ating program or operating mode, this is possible via the
menu.
»
Open the menu.
»
Select the heating circuit for which you want to make
a change.
»
Select “Settings”.
»
Make the required settings.
»
Return to the main screen.
11.4 Seasonal operation
It is possible to switch between the following options:
►
Only cooling enabled
►
Only heating enabled
Parameters
Description
Only cooling
enabled
Only cooling mode is enabled. There is no heating.
Control takes place in accordance with the set
cooling curve.
This setting prevents heating mode from starting
up, for example on a cold summer day.
Parameters
Description
Only heating
enabled
Only heating mode is enabled. There is no cooling.
Control takes place in accordance with the set
heating curve.
This setting prevents cooling mode from starting
up for example on sunny winter days when the out-
door temperature sensor is warmed by the sun.
Cooling and
heating ena-
bled
Both heating and cooling are provided. Control
takes place in accordance with the set heating and
cooling curve.
11.4.1 Setting seasonal operation
“Seasonal operation” can be activated directly on the main
screen of the relevant heating circuit.
»
Open the main screen of the heating circuit you want
to change.
»
Press the sun/snowflake symbol.
1
Sun/snowflake symbol
»
Make the required settings.
»
Return to the main screen.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...