BA-982018-AIR FALCON-OTS-EN | www.ochsner.com 67
Silent mode
Note
If the operating program of the heat pump is set to
“OFF” when there is a heat demand, the next active
heat generator will be used. This is normally the
electric auxiliary heater. This can result in exces-
sive running costs.
»
Switch off the heat pump only in an emergen
-
cy.
»
Switch off the heating and DHW circuits via
the respective operating program.
29.1.1 Setting the operating program
»
Open the menu.
»
Select “Heat pump”.
»
Select “Operating program”.
»
Select “Operating program heat pump”.
»
Make the required settings.
»
Return to the main screen.
29.2 Operating data
In this submenu, you can view the individual data of the
heat pump. The values in this menu cannot be changed.
Description
Unit
Heat pump oper-
ating status
The status of the heat pump is displayed
here.
-
Off
The heat pump is switched off.
Heating
The heat pump is in heating mode.
Cooling
The heat pump is in cooling mode.
DHW
The heat pump is in DHW mode.
Defrost
The heat pump is in defrosting mode.
Electricity tar-
iff shutdown
An electricity tariff shutdown of the heat
pump has taken place.
Manual heat-
ing
The heat pump is in the following oper-
ating program: “Manual heating”
This operating program can only be set
by OCHSNER Customer Service and
should only be used for testing purpos-
es.
Manual cool-
ing
The heat pump is in the following oper-
ating program: “Manual cooling”
This operating program can only be set
by OCHSNER Customer Service and
should only be used for testing purpos-
es.
Outdoor
temperature
shutdown
The heat demand is blocked by the out-
door temperature.
Operat-
ing mode
changeover
The heat pump switches from one oper-
ating mode to another.
Starting pro-
cedure
Operation of the heat pump starts.
Description
Unit
Standby
There is no heating, cooling or DHW
demand.
Shutdown
procedure
Operation of the heat pump ends.
Fault
There is a fault.
Operating
program
switched off
The heat pump was switched off by se-
lecting the following operating program:
“Off”
Minimum sys-
tem pressure
The system pressure fell below the
permissible minimum. If the system
pressure is too low, the operability may
be impaired and the heat exchanger
may be damaged in cooling mode. Con-
trol the system pressure and top up the
heating water if required.
Heat pump flow
temperature
The flow temperature, upstream of the
integrated electric auxiliary heater, is
displayed here.
°C
Flow temperature
auxiliary heater
The flow temperature, downstream of
the integrated electric auxiliary heater, is
displayed here.
°C
Heat pump return
temperature
The return temperature is displayed
here.
°C
Heat sink system
flow rate
The current flow rate of the heat sink
system is displayed here.
m
3
/h
System pressure,
heat sink system
The current system pressure of the heat
sink system is displayed here.
bar
Evaporator intake
air
The intake air temperature at the out-
door unit of an air/water heat pump is
displayed here.
°C
Evaporator dis-
charge air
The discharge air temperature at the
outdoor unit of an air/water heat pump is
displayed here.
°C
Successful de-
frosting
The number of successful defrosting
attempts is displayed here.
-
Successful de-
frosting today
The number of successful defrosting
attempts for the current day is displayed
here.
-
Heating output
The heating output is displayed here.
Switching cycles
Absolute switching cycles are displayed
here.
-
Switching cycles
today
The switching cycles for the current day
are displayed here.
-
Power consump-
tion
The current power consumption of the
heat pump is displayed here.
kW
29.2.1 Viewing operating data
»
Open the menu.
»
Select “Heat pump”.
»
Select “Operating data”.
30. Silent mode
For the AIR FALCON, it is possible to select a mode that
will reduce the noise level at the outdoor unit.
Содержание AIR FALCON 212
Страница 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 65: ...OTS_EN www ochsner com 65 Expert mode...
Страница 77: ...OTS_ZSM_EN www ochsner com 77...
Страница 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Страница 86: ...Notes...
Страница 87: ...Notes...