Chapter 25: LPC82x Flash In-System and In-Application Programming
25.6.1.1 Unlock <Unlock code>
25.6.1.2 Set Baud Rate <Baud Rate> <stop bit>
Table 312. UART ISP command summary
ISP Command
Usage
Described in
Unlock
U <Unlock Code>
Set Baud Rate
B <Baud Rate> <stop bit>
Echo
A <setting>
Write to RAM
W <start address> <number of bytes>
Read Memory
R <address> <number of bytes>
Prepare sector(s) for
write operation
P <start sector number> <end sector number>
Copy RAM to flash
C <Flash address> <RAM address> <number of bytes>
Go
G <address> <Mode>
Erase sector(s)
E <start sector number> <end sector number>
Blank check sector(s)
I <start sector number> <end sector number>
Read Part ID
J
Read Boot code version
K
Compare
M <address1> <address2> <number of bytes>
ReadUID
N
Read CRC checksum
S <address> <number of bytes>
Table 313. UART ISP Unlock command
Command
U
Input
Unlock code: 23130 (decimal)
Return Code
CMD_SUCCESS |
INVALID_CODE |
PARAM_ERROR
Description
This command is used to unlock Flash Write, Erase, and Go commands.
Example
"U 23130<CR><LF>" unlocks the Flash Write/Erase & Go commands.
Table 314. UART ISP Set Baud Rate command
Command
B
Input
Baud Rate: 9600 | 19200 | 38400 | 57600 | 115200
Stop bit: 1 | 2
Return Code
CMD_SUCCESS |
INVALID_BAUD_RATE |
INVALID_STOP_BIT |
PARAM_ERROR
Description
This command is used to change the baud rate. The new baud rate is effective
after the command handler sends the CMD_SUCCESS return code.
Example
"B 57600 1<CR><LF>" sets the serial port to baud rate 57600 bps and 1 stop bit.