3 Options
BU 0200 GB
Subject to technical alterations
87
3.5.4
I/O Extension, SK TU4-IOE, ...-M12
The internal I/O units can record sensor and actuator signals. These can be used for a drive function or
forwarded to a host bus system (e.g. Profibus or CANopen). Up to two I/O modules (and combinations: 1 x
SK CU4-IOE and 1 x SK TU4-IOE) can be connected to an inverter (up to hardware version V1.1 R1 and
firmware version V1.0 R1 of the I/O - extension and firmware version V1.1 R2 of the frequency inverter only
the evaluation of one I/O - extension is possible for each frequency
inverter.).
The I/O extension SK TU4-IOE-… requires an SK TI4-TU-BUS
Adapter Unit. Communication with the frequency inverter(s) is via
the system bus. All connections (power supply, system bus,
sensors,...) are made via the terminal block of the BUS Adapter
Unit. The M12-versions of the I/O - extension (SK TU4-IOE-
M12
)
also provide M12 connections for each of the digital inputs and
outputs on the front side.
•
4x digital inputs
•
2x analog inputs
•
2x digital outputs
•
1x analog output
•
Status LEDs: BG status, BG fault
•
Additional LEDs, M12 version: Dig. In 1 - 4, Dig. Out 1 - 2
•
DIP switches for selection
0 - 10V, -10 - 10V, 0 - 20mA, 4 - 20mA
•
DIP switches for: addressing, bus termination
Control connections SK TU4-IOE(-…)
The double spring terminal block of the BUS -Adapter Unit
is
colour coded to indicate the
three
different
potential levels
.
A separate voltage source should be used to supply the DOs. However, it is also possible to implement the
supply of the DOs by bridging the 24V o and GND o with one of the terminals of the system bus level (24V
and GND). However, in this case it should be noted that this produces an increased risk of errors on the bus
cables.
The sensors and actuators are connected to the terminal block. Alternatively, the SK TU4-IOE
-M12
module
enables connection of the digital I/Os via the M12 round plug connectors (Socket, 5-pin, A-coded) on the
front of the module.
Double
use
of the inputs via the terminal block and the M12 round plug
should be avoided
.
Analog IOs
System bus level and digital inputs
Digital outputs
10VA
AIN1+
AIN1-
GND A
AOUT
24V
24V
(as 11)
GND
GND
DIN 1
GND
24V
(as
11)
DIN 2
GND
24V
(as
11)
24V
O
DO
DO 1
GND
O
DO
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
10VA
AIN2+
AIN2-
GND A
PE
24V
(as
11)
Sys+
Sys-
GND
DIN 3
GND
24V
(as
11)
DIN 4
GND
24V
(as
11)
GND
O
DO
DO 2
GND
O
DO
Terminal block of the bus Adapter Unit
SK TI4-TU-BUS and assignment of functions
Potential level: Analog I/O
Potential level: System bus
Potential level: DOs
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...