6 Parameterisation
BU 0200 GB
Subject to technical alterations
185
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P546
Func
tion
Bus setpoint 1 ... 3
S
P
In this parameter, a function is assigned to the output setpoint during bus actuation.
NOTE:
For further details, please refer to the relevant bus manual or the description for
(P400). (Values from 0% … 100% correspond to 0000
hex
… 4000
hex
,)
For standardisation of the setpoint values: See also (Section 9.10).
[-01] = Bus setpoint
value
1
[-02] = Bus setpoint
value
2
(only for PPO type 2 or 4)
[-03] = Bus setpoint
value
3
(only for PPO type 2 or 4)
Possible setting values:
0 ... 24
{ [-01] = 1 }
{ [-02] = 0 }
{ [-03] = 0 }
0 =
Off
1 =
Setpoint frequency
(16 Bit)
2 =
Frequency addition
3 =
Frequency subtract
ion
4 =
Minimum frequency
5 =
Maximum frequency
6 =
Cur
rent
val
ue
, process c
on
tr
o
l
ler
7 =
Nom
inal
val
ue
, process c
on
tr
o
l
ler
8 =
PI current frequency
9 =
PI limited current freq
uency
10 =
PI sup
e
rv
i
s
e
d cur
rent
freq
uency
11 =
Torque current limit
ation
(limited)
12 =
Torqu
e
curr
ent
limit
ation
(switch-
off
)
13 =
Current limit
(limited)
14 =
Current limit
(switch-
off
)
15 =
Ramp time
16 =
Pre-tension torque ((P214) multiplication)
17 =
Multiplication
18 =
Curve control
(Curve travel calculator)
19 =
Servo mode torque
20 =
BusIO InBits 0-7
21 =
..24 reserved for Posicon
31 =
Digital output
first
IOE
(sets status DOUT)
32 =
Analog output
first
IOE
(sets value AOUT)
P549 Pot
entiometer
Box function
S
This parameter provides the possibility of adding a correction value (fixed frequency, analog,
bus) to the current setpoint value by means of the SimpleBox/ParameterBox keyboard.
The adjustment range is determined by the auxiliary setpoint value P410/411.
0 ... 3
{ 1 }
0 = Off
1 = Setpoint frequency
, with(P509)
≠
1
control via USS is possible
2 = Frequency addition
3 = Frequency subtract
ion
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...