9 Additional Information
BU 0200 GB
Subject to technical alterations
249
9.6 Operation with FI circuit breakers
With SK 200E frequency inverters (except 115V devices) leakage currents of > 40mA are to be expected
with an active mains filter. If possible, an FI circuit breaker for the protection of personnel should not be used.
If the frequency inverter is to be used with an FI circuit breaker for the protection of personnel, the leakage
currents to earth must be reduced to 10 - 20 mA by means of jumpers. However, with "operation on an IT
network" the FI loses its specified degree of interference protection.
Further details can be found in Section 2.7.5 - 2.7.6.
9.7 System bus
Frequency inverters and components of the SK 200E series communicate with each other via the system
bus. This bus system is a CAN bus with a Canopen protocol. Up to four frequency inverters and their
associated components (field bus module, absolute encoder, I/O modules etc.) can be connected to the
system bus. Integration of the components into the bus does not require any BUS-specific knowledge on the
part of the user.
It is only necessary to take care that the correct physical structure of the bus system and the correct
addressing of the participants are complied with.
The connection of the individual NORD components is described in this manual
(See section 2.8.2, 3.4, and 3.5).
Physical structure
Standard CAN
Bus length
20m with a wire cross section of 0.25mm² (AWG23)
Structure preferably
linear
Spur cables
possible, (max. 6m)
Termination resistors
120
Ω
, 250mW at both ends of a system bus
(with SK 200E-… or SK xU4-… via DIP switches)
Baud rate
250kBaud - preset
SYSTEM BUS
Configuration Example
1. FI
2. FI
3. FI
4. FI
1. I/O
Extension
8. I/O
Extension
Field Bus
Option
additional participants
(I/O extensions, CANopen encoder
Note:
Terminal77 = System bus + (CAN H)
Terminal78 = System bus - (CAN L)
Terminal numbers may differ
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...