NORDAC SK 200E Manual
184
Subject to technical alterations BU
0200
GB
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P542
[-01]
[-02]
Set analog out
put
S
0.0 ... 10.0 V
{ all 0.0 }
[-01] =
First IOE,
AOUT of the first I/O extension (SK xU4-IOE)
[-02] =
Second IOE,
AOUT of the second I/O extension (SK xU4-IOE)
... only with
SK CU4-IOE or
SK TU4-IOE
The analog output of the FI can be set with this function, independently of the actual operating
state. To do this, the relevant analog output must be set to the function "External control"
(P418 = 7).
This function can either be used manually or in combination with a bus control. The value set
here will, once confirmed, be produced at the analog output.
P543
[-01]
...
[-03]
Actual bus value 1… 3
S
P
In this parameter the returned value on bus actuation can be selected.
NOTE:
For further details, please refer to the relevant bus manual or the description for
(P418). (Values from 0% … 100% correspond to 0000
hex
… 4000
hex
)
For standardisation of the actual values: See also (Section 9.10).
[-01] = Actual bus value 1
[-02] = Actual bus value 2
(only for PPO type 2 or 4)
[-03] = Actual bus value 3
(only for PPO type 2 or 4)
Possible setting values:
0 ... 22
{ [-01] = 1 }
{ [-02] = 4 }
{ [-03] = 9 }
0 =
Off
1 =
Actual frequency
(x=4000
hex
*f[Hz]/(P105))
2 =
Actual speed
(x=4000
hex
*n(rpm]/(P202))
3 =
Current
(x=4000
hex
*I[A]/(P203))
4 =
Torque current
(100% = P112)
(x=4000
hex
*Iq[A]/(P112)*100/
√
((P203)²+(P209)²)
5 =
Digital IO status
4
6 =
... 7 reserved
8 =
Setpoint frequency
(x=4000
hex
*fs[Hz]/(P105))
9 =
Error code
10 =
... 11 reserved
12 =
Bus IO Out Bits 0..-7
13 =
... 16 reserved
17 =
Analog input value 1
(AIN1 of the first I/O extension
SK xU4-IOE (P400 [-03]))
18 =
Analog input value 2
(AIN2 of the first I/O extension
SK xU4-IOE (P400 [-04]))
19 =
Setpoint
freq
uency
master value
(P503)
(x=4000
hex
*fs[Hz]/(P105))
20 =
Set
point
freq
uency
after ramp
,
master value
(x=4000
hex
*fsnr[Hz]/(P105))
21 =
Act
ual
freq
uency
w
ith
o
ut
slip
master
value
(x=4000
hex
*f-f2[Hz]/(P105))
22 =
Speed
from
speed
encoder
(x=4000
hex
*n[Hz]/(P105)/(60/p))
p=pole-pair number,
Determined from (P201) and (202))
4
The assignment of the dig. inputs for P543 = 5
Bit 0 = DigIn 1
(FI)
Bit 1 = DigIn 2
(FI)
Bit 2 = DigIn 3
(FI)
Bit 3 = DigIn 4
(FI)
Bit 4 = PTC input
(FI)
Bit 5 = DigIn 5
(DI1, 1. SK…IOE)
Bit 6 = DigIn 6
(DI2, 1. SK…IOE)
Bit 7 = DigIn 7
(DI3, 1. SK…IOE)
Bit 8 = DigIn 8
(DI4, 1. SK…IOE)
Bit 9 = reserved
Bit 10 = reserved
Bit 11 = reserved
Bit 12 = DigOut 1
(FI)
Bit 13 = mech. brake
(FI)
Bit 14 = DigOut 2
(DO1, 1. SK…IOE)
Bit 15 = DigOut 3
(DO2, 1. SK…IOE)
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...