6 Parameterisation
BU 0200 GB
Subject to technical alterations
159
6.1.5
Control terminals
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P400
[-01]
...
[-09]
Setpoint i
n
p
ut
funct
ion
P
0 ... 33
{ [-01] = 1 }
{ [-02] = 15 }
{ [-03] = 0 }
{ [-04] = 0 }
{ [-05] = 1 }
{ [-06] = 0 }
{ [-07] = 1 }
{ [-08] = 0 }
{ [-09] = 0 }
[-01] =
Potentiometer 1
, function of the potentiometer integrated in the FI (Section. 5.1.3).
The DIP switches 4/5 must be set to “off” (Section 5.1.1) in order for the function to
be influence by this parameter setting.
[-02] =
Potentiometer 2
, function of the potentiometer integrated in the FI (Section 5.1.3).
The DIP switches 4/5 must be set to “off” (Section 5.1.1) in order for the function to
be influence by this parameter setting.
[-03] =
Ext
ernal
analog in
put
1
, AIN1 of the first I/O extension (SK xU4-IOE).
[-04] =
Ext
ernal
analog in
put
2
, AIN2 of the first I/O extension (SK xU4-IOE).
[-05] =
Setpoint module
, in preparation
[-06] =
Digital input 2
, can be set to impulse signal evaluation via the parameter P420 [-
02] =26 or 27. The impulses can then be evaluated as an analog signal in the FI
according to the function set here.
[-07] =
Digital input 3
, can be set to impulse signal evaluation via the parameter P420 [-
03] =26 or 27. The impulses can then be evaluated as an analog signal in the FI
according to the function set here.
[-08] =
Ext
ernal
a
nalog
i
nput
1 2nd IOE
, AIN1 of the second I/O extension
(SK xU4-IOE) (= analog input 3).
[-09] =
Ext
ernal
a
nalog
i
nput
2 2nd IOE
, AIN2 of the second I/O extension
(SK xU4-IOE) (= analog input 4).
...Settings as follows.
The basic equipment of SK 200E devices does not include an analog input. An analog function
can only be implemented by the use of options (Array [-01]...[-05] and [-08]…[-09]) or by use of
the digital input 2 or 3 (Array [-06]...[-07]). The following settings are then possible:
For standardisation of actual values: See also (Section 0).
0 = Off
, the analog input has no function. After the FI has been enabled via the control
terminals, it will supply the set minimum frequency (P104).
1 = Set point frequency
, the specified analog range (P402/P403) varies the output
frequency between the set minimum and maximum frequencies (P104/P105).
2 = Frequency addition **
, the supplied frequency value is added to the setpoint.
3 = Frequency subtract
ion
**
, the supplied frequency value is subtracted from the setpoint.
4 = Minimum frequency
, is a typical setting value for the function of the potentiometers P1
or P2 (P400 [01] or [02]), which are integrated in the cover of the FI (Section 5.1.3).
Standardisation: T_Min.-frequency= 50Hz*U[V]/10V (U=voltage potentiometer (P1 or P2))
5 = Maximum frequency
, is a typical setting value for the function of the potentiometers P1
or P2 (P400 [01] or [02]), which are integrated in the cover of the FI (Section 5.1.3).
Standardisation: T_Max.-frequency= 100Hz*U[V]/10V (U=voltage potentiometer (P1 or P2))
6 = Cur
rent
val
ue
process c
on
tr
o
l
ler
*, activates the process controller analog input is
connected to the actual value sensor (compensator, air can, flow volume meter, etc.).
The mode is set via the DIP switches of the I/O extension or in (P401).
7 = Nom
inal
val
ue
process c
on
tr
o
l
ler
*
, as function 6, however the setpoint is specified
(e.g. by a potentiometer). The actual value must be specified using another input.
8 = Current freq
uency
PI
*,
9 = Current freq
uency,
l
imi
t
e
d
by
PI
*,
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...