3 Options
BU 0200 GB
Subject to technical alterations
101
Example for the connection of SK TU4-DEV to SK 200E
NOTE
Looping of the 24V supply voltage
(terminals 11/15)
is in principle possible, however, a
maximum current load of
3A
for the
SK TU4-DEV(-…)
must not be exceeded!
Detail of the M12 connections of the SK TU4-DEV-M12
The special wiring of the M12 round plug connectors enables the connection of both single and double
sensors, which are equipped with normal M12 system plugs with standard sensor/actuator wiring.
If the M12 round plug connectors
are used, the terminal block
connections for the digital inputs
(terminals 19, 20, 25, 26) must
not be used.
Wiring of the M12-plug
connector to
SK TU4-…-M12
SK 205E…-Connection unit (SK TI4…)
SK TU4-DEV…-Connection unit (SK TI4-TU-BUS)
Voltage
Source
24V DC
Voltage
Source
24V DC
DeviceNet
Subscriber
X+1
DeviceNet
Subscriber
X-1
Coupling detail