NORDAC SK 200E Manual
200
Subject to technical alterations BU
0200
GB
6.2.2
Information
(I/O - extension)
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P170
...
[-01]
...
[-02]
Actual error
0 ... 9999
Actual fault present. Further details in Section 7 "Operating status messages".
… [-01 ]
= Actual module fault
… [-02 ]
= Last module fault
Possible displayed values:
1000 =
EEPROM error
1030 =
Systembus Bus Off
2000 =
DIP changed
2001 =
DIP configuration error / not permissible
2010 =
Analog output error
P171
... [-01]
...
...
[-03]
Software version/ revision
0.0 ... 9999.9
This parameter shows the software and revision numbers in the module. Array [-03] provides
information about any special versions of the hardware or software A zero stands for the
standard version.
… [-01] = Software version 1
Version number
:
(e.g.: V
1.0
)
… [-02] = Software version 2
Version number
:
(e.g.:
R
1
)
… [-03] = Software version 3
Version number
:
(e.g.:
0
)
P172 Configuration
This parameter displays the functions or variants integrated into the module.
0 ... 2
1 = Internal bus module
(SK CU4-…)
2 = External bus module
(SK CU4-…)
3 = BUS Technology Unit via SPI
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...