3 Options
BU 0200 GB
Subject to technical alterations
85
3.5.2
Mains Unit, SK TU4-24V-…
The Mains Unit is used for the production of the 24V control voltage for the FI from the available mains
voltage (115V/ 230V/380V/500V). With this, a separate external 24V control voltage is not necessary.
An analog output is also available for the connection of a potentiometer.
•
Mains unit for 100-240V, SK TU4-24V-123-B
•
Mains unit for 380-500V, SK TU4-24V-140-B
• +24V-
output
voltage
•
1x analog input (e.g. potentiometer)
•
1x impulse output
•
Status LED = 24V
•
Max. permissible continuous current: 420mA
The Mains unit SK TU4-24V-…can only be used in combination with an SK TI4-TU-NET adapter unit.
Details of the control connection are described in the Section for the Adapter Unit (Section 3.5.1.2)
A connection and parameterisation example is described in Section 3.4.1.
To process current setpoint values (0(4)-20mA), the enclosed bag contains a 500
Ω
resistor, for connection
between terminals 11 and 14. Matching of the relevant input of the frequency inverter is made via parameter
(P420).
Setpoint
Parameter [Array]
Setting
0 … 20mA P420 [-02] or [-03] {26}
4 … 20mA P420 [-02] or [-03] {27}
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...