6 Parameterisation
BU 0200 GB
Subject to technical alterations
177
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P504 Pulse
frequency
S
The internal pulse frequency for actuating the power component can be changed with this
parameter. A higher setting reduces motor noise, but leads to increased EMC emissions and
reduction of the possible motor nominal torque.
NOTE:
The radio interference suppression limiting curve A1 according to EN55011 is
complied with at a setting of 6.0kHz on condition that the wiring guidelines are
complied with. For further details, see Section 9.4 EMC limit value classes.
3.0 ... 16.0 kHz
{ 6.0 }
NOTE:
Raising the pulse frequency leads to a reduction of the possible output current,
depending on the time (I
2
t curve). For further details, see Section 9.5 Reduced
output power.
P505 Absolute
mini
mum
freq
uency
S
P
0.0 ... 10.0 Hz
{ 2.0 }
Gives the frequency value that cannot be undershot by the FI. If the setpoint is smaller than the
absolute minimum frequency, the FI switches off or changes to 0.0Hz.
At the absolute minimum frequency, braking control (P434) and the setpoint delay (P107) are
actuated. If a setting value of "Zero" is selected, the brake relay does not switch during
reversing.
When controlling lift equipment, this value should be set at a minimum of 2Hz. From 2Hz, the
current control of the FI operates and a connected motor can supply sufficient torque.
NOTE:
Output frequencies < 4.5Hz result in a reduced current overload capacity. For
further details, see Section 9.5 power derating.
P506
Automatic
error
acknowled
gement
S
0 ... 7
{ 0 }
In addition to the manual error acknowledgement, an automatic acknowledgement can also be
selected.
0 = No automatic
error acknowledgement
1 ... 5 = Number
of permissible automatic error acknowledgments within one mains-on cycle.
After mains off and switch on again, the full amount is again available.
6 = always
, an error message will be acknowledged automatically if the cause of the error is
no longer present.
7 = quit disable
(via enable deactivated)
, acknowlegement is only possible with the OK
key or by switching off the mains. Acknowledgement is not implemented by removing
the enable!
Содержание SK 200E Series
Страница 1: ...GB BU 0200 NORDAC SK 200E Frequency inverter manual Quick commissioning page 123...
Страница 2: ...NORDAC SK 200E Manual 2 BU 0200 GB...
Страница 54: ...NORDAC SK 200E Manual 54 Subject to technical alterations BU 0200 GB 2 9 5 EC declaration of conformity...
Страница 138: ...NORDAC SK 200E Manual 138 Subject to technical alterations BU 0200 GB 5 4 6 Certificate...
Страница 262: ...NORDAC SK 200E Manual 262 BU 0200 GB...
Страница 263: ...10 Keyword index BU 0200 GB 263...
Страница 264: ...NORDAC SK 200E Manual 264 BU 0200 GB Part No 607 2002 1310...
Страница 265: ...The Nordac SK 200E is available to order from www inverterdrive com...