3.5 Setting Screen Reference
3
-
91
ZA 57630
■ [SHORT CORR]
: Set short correction.
This sets the short correction function. It can be set when the measurement mode is
IMPD−EXT, IMPD−3T and IMPD−2T.
○ Setting procedure
<Numerical settings (requiring confirmation)>, <Numerical settings>
○ Functions of function keys
・
[ON/OFF]
: Enable or disable short correction.
・
[MEASURE]
: Start correction data measurement (when measurement mode is
IMPD−3T and IMPD−2T only).
・
[COPY TO REF8]
: Copy the short correction data to reference data 8 (REF8).
・
[EDIT]
: Set the short correction data number with the numerical input palette.
・
[MODIFY]
: Modify the short correction data number with the knob or cursor keys.
The currently set short correction data number is displayed in the menu. When short
correction is turned off, the short correction data number indication becomes “OFF”.
For details on short correction, refer to
“1.8.4 Short Correction”
in
Instruction Manual (Advanced)
.
■ [LOAD CORR]
: Set load correction.
This sets the load correction function. It can be set when the measurement mode is
IMPD−EXT, IMPD−3T and IMPD−2T.
■ [LOAD CORR]
-
[FUNCTION]
: Set load correction.
Enable or disable the load correction function.
○ Setting procedure
<Numerical settings (requiring confirmation)>, <Numerical settings>
○ Functions of function keys
・
[ON/OFF]
: Enable or disable load correction.
・
[MEASURE]
: Start correction data measurement (when measurement mode is
IMPD−3T and IMPD−2T only).
・
[COPY TO REF8]
: Copy the load correction data to reference data 8 (REF8).
・
[EDIT]
: Set the load correction data number with the numerical input palette.
・
[MODIFY]
: Modify the load correction data number with the knob or cursor keys.
The currently set load correction data number is displayed in the menu. When load
correction is turned off, the load correction data number indication becomes “OFF”.
When load correction is enabled, this instrument will operate with open correction and short
correction both forcibly enabled internally even if those functions were set to off (disabled).
For details on load correction, refer to
“1.8.5 Load Correction”
in
Instruction Manual
(Advanced)
.
Содержание ZA57630
Страница 1: ...NF Corporation IMPEDANCE ANALYZER ZA57630 INSTRUCTION MANUAL BASICS...
Страница 2: ......
Страница 3: ...IMPEDANCE ANALYZER ZA57630 INSTRUCTION MANUAL BASICS DA00068820 003...
Страница 22: ...1 8 ZA57630 Blank...
Страница 28: ...2 2 Assembly and Installation 2 6 ZA 57630 Figure 2 1 Rack Mount Kit Assembly Drawing JIS...
Страница 29: ...2 2 Assembly and Installation 2 7 ZA 57630 Figure 2 2 Rack Mount Kit Assembly Drawing EIA...
Страница 30: ...2 2 Assembly and Installation 2 8 ZA 57630 Figure 2 3 Rack Mount Dimensions JIS...
Страница 31: ...2 2 Assembly and Installation 2 9 ZA 57630 Figure 2 4 Rack Mount Dimensions EIA...
Страница 36: ...2 14 ZA 57630 Blank...
Страница 224: ...5 14 Miscellaneous Specifications 5 40 ZA57630 Figure 5 1 External dimensions...
Страница 240: ...XVI ZA57630 Blank...
Страница 242: ......
Страница 244: ......
Страница 245: ......
Страница 246: ...http www nfcorp co jp NF Corporation 6 3 20 TsunashimaHigashi Kohoku ku Yokohama223 8508JAPAN...