4. Advanced Operation
PROGRAMMABLE AC/DC POWER SOURCE
126
It is necessary for an electric device with a large inrush current to use a power source with a
sufficient current supplying capability. With a power source that cannot supply a sufficient inrush
current, some electric devices may not start as they are not supplied with necessary power.
This product has the ability to supply peak current up to four times of the RMS rating. You can
measure the maximum inrush current value using the current peak-hold function of the product.
4.5.2 Basics
Output current peak-hold function holds either a positive or negative peak value, whichever is
larger in absolute value.
Current peak-hold value is displayed in all of the Average, RMS, and Peak measurement views
in the Normal View.
Clearing function for the current peak-hold value is provided. The clear operation clears the
current peak-hold value (all phases) to 0 Apk.
--------
Notes
------------------------------------------------------------------------------------------------------------
The peak hold value starts to update again immediately after the clear operation. The clear
operation may not turn the current peak-hold value to 0 Apk even when no current is being
output, because of noise or other reasons.
-----------------------------------------------------------------------------------------------------------------------------
4.5.3 Measurement Method
Operation procedure
1.
Before turning on the output, clear the current peak-hold value. Following two methods are
available.
(a)
Shortcut operation:
+
(b)
Select the [Measure] soft-key
[2: Measure]. Hover the cursor over [Exec] of the [Ipk-H
Clr] item and press the ENTER key.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...