10.5 AC Output
KP3000S
239
10.5 AC
Output
[V]=Vrms, [A]=Arms, and the power supply input voltage is 200 V, unless otherwise noted.
KP3000S
Mode Single-phase
two-wire
Floating output, the Lo terminal can be grounded.
Rated output voltage
100 V / 200 V
Voltage setting range
0.0 V to 155.0 V / 0.0 V to 310.0 V
0.0 Vp-p to 440.0 Vp-p / 0.0 Vp-p to 880.0 Vp-p (arbitrary wave)
Setting
resolution
0.1
V
Voltage accuracy
*1
(0.5% of set + 0.6 V / 1.2 V)
Maximum current *2
30 A /15 A
Maximum peak current
*3
Peak value which is four times of the maximum current (Apk)
Power capacity
3 kVA
Load power factor
0 to 1 (phase lead or phase lag, 45 Hz to 65 Hz, external power injection
and regeneration are not available.)
Frequency setting
range
40.00 Hz to 550.00 Hz (AC mode)
1.00 Hz to 550.00 Hz (AC+DC mode)
Setting
resolution
0.01
Hz
Frequency accuracy
0.01% of set (23°C
5°C)
Frequency stability *4
0.005%
Voltage frequency
characteristic *5
1%
Output waveform
sine wave, arbitrary wave (16 types), clipped sine wave (3 types)
Output on phase
0.0°
to 359.9° variable (setting resolution 0.1°)
Output off phase
0.0°
to 359.9° variable (setting resolution 0.1°, active/inactive selectable)
DC offset
*6
Within
20 mV (typ. fine adjustment available)
*1: In the case of 10 V to 150 V/20 V to 300 V, sine wave, no load, 45 Hz to 65 Hz, DC voltage
setting 0 V, 23°C
5°C.
*2: If the output voltage is higher than the rated value, this is limited (lowered) to satisfy the power
capacity. If there is the DC superimposition, the active current of AC+DC satisfies the
maximum current. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient
temperature is 40°C or higher, the maximum current may decrease.
*3: For the capacitor input type rectified load (crest factor=4), the rated output voltage, and 45 Hz
to 65 Hz.
*4: For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum
current, and the operating temperature.
*5: For 40 Hz to 550 Hz, sine wave, the rated output voltage, the resistance load for the maximum
current at 55 Hz, and 55 Hz reference.
*6: In the case of the AC mode and 23°C
5°C.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...