8. Troubleshooting
PROGRAMMABLE AC/DC POWER SOURCE
228
Table 8-3 Actions When a Failure is Suspected (Continued)
Category Symptom
Possible
Cause Necessary
Actions
Sequence/
Simulation-
related
problem
The Sequence
cannot be
started.
The output is off.
Turn on the output, then start the
sequence.
The specified
Step Time is
exceeded.
The Stop Phase is
enabled.
When the stop phase setting is
active, the execution waits for the
Step Time that was set pass, and
keeps the output setting until it
reaches the Stop Phase that was
set, and then transitions to the
next step. As the result, the actual
step time is longer than the set
Step Time. To move to the next
step immediately after the Step
Time, disable the Stop Phase.
4.2
Problem of
polyphase
system
The polyphase
system is not
recognized at
start-up.
The System Cable is not
connected properly.
Check the System Cable
connection for any disconnected
connector, and so on.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...