10.14 Setting Range Limit Function
KP3000S
247
10.14 Setting Range Limit Function
This is the limit function for the setting of the internal signal source. It works when the signal source
is INT, VCA (frequency setting limit only), SYNC (voltage setting limit only), or ADD (internal
signal source only). The limitation does not work for the Sequence and Simulation. It does not also
work for the external signal source of EXT and ADD.
In the polyphase system, the setting is common to all the phases.
Voltage setting limit 1 (in the AC mode, and sine wave or clipped sine wave is selected)
KP3000S
Setting range
(effective value)
Phase voltage setting
0.1 V to 155.0 V / 0.1 V to 310.0 V
Line voltage setting (single-phase three-wire)
0.2 V to 310.0 V / 0.2 V to 620.0 V
Line voltage setting (three-phase four-wire)
0.2 V to 268.4 V / 0.2 V to 536.8 V
Factory default
Phase voltage setting, 155.0 V/310.0 V
Resolution
Phase voltage setting: 0.1 V, line voltage setting: 0.2 V
Note: The line voltage setting is available only when the output voltage setting is set as the line
voltage and sine wave is selected in the balanced mode of the polyphase system.
Voltage setting limit 2 (other than Voltage setting limit 1, phase voltage setting only)
KP3000S
Positive
voltage
Setting Range
(Peak value)
+0.1 V to +220.0 V / +0.1 V to +440.0 V
Factory default
+220.0 V / +440.0 V
Negative
voltage
Setting Range
(Peak value)
220.0 V to
0.1 V /
440.0 V to
0.1 V
Factory default
220.0 V /
440.0 V
Resolution 0.1
V
Note: The limitation is applied to the additional values of the AC voltage setting (recalculated to a
peak value) and the DC voltage setting.
Frequency setting limit (the lower limit
the upper limit)
KP3000S
Upper
limit
Setting Range
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
Factory default
550.00 Hz
Lower
limit
Setting Range
1.00 Hz (AC mode : 40.00 Hz) to 550.00 Hz
Factory default
1.00 Hz (AC mode : 40.00 Hz)
Resolution 0.01
Hz
Note: In the AC mode, the setting range is 40.00 Hz to 550.00 Hz.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...