4.22 Enabling
Automatic
Output-On at Power-On
You can set the automatic output-on after power-on. If you set the output-on at power-on setting to
[ON], the message window as shown in Figure 4–24 is displayed for about 10 seconds after you turn
on the power and the self check at start-up, until the output becomes on automatically. If you press
the ENTER key in the control panel, CANCEL key, or the soft-key under the [Cancel] button in the
message window during this process, the output-on at power-on setting is set to off and the output is
not enabled automatically. If you do not perform this key operation, the output on is enabled
automatically after the message window is closed.
--------
Notes
------------------------------------------------------------------------------------------------------------
The output-on at power-on setting is valid only in the Continuous function. If you set so that
the Sequence or the Simulation function is selected at power-on (see
4.2.10
and
4.3.10
), the
output is not turned on automatically when turning on the power even if the output-on at
power-on setting is set to on.
If the unit is in the Remote state immediately after the start-up, the output-on at power-on
setting is set to off and the output is not turned on automatically. The message window shown
in Figure 4-24 is not displayed.
If the unit enters the Remote state while the message window shown in Figure 4-24 is
displayed, this message window closes and the output-on at power-on setting is set to off,
therefore the output is not turned on automatically.
-----------------------------------------------------------------------------------------------------------------------------
Figure 4-24 The Message Window to be Shown Before the Automatic Output-On After
the Power-On
Operation procedure
1.
Press the MENU key to move to the root menu, then select [System]. The system setting
window opens.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...