4.2 Using Sequence Function
KP3000S
71
Step Behavior (Const, Keep, Sweep)
For the intra-Step parameter other than waveforms and phases, the following three patterns can be
set as the method to change values in the step.
Constant (Const)
Fixed to the value set in the step.
Keep (Keep)
Keeping the value immediately before transitioning to the step. That is, the value is changed
depending on the status of the previous step. Although the parameter value can be set even if
the operation type setting is Keep, the parameter setting value is ignored when sequence is
executed.
Sweep
It changes linearly from the value immediately before transitioning to the value set in the step,
taking the Step Times. In other words, it reaches the setting value after the Step Time passes in
the step. The starting value is changed depending on the status of the previous step.
Previous step
Next step
Previous step
Next step
Previous step
Next step
Used as the setting
value in the next step
Keeps the final value
of the previous step
Changes from the final value of
the previous step to the setting
value of the next step
Cons
t
Keep
Sweep
Setting
value
Setting
value
Figure 4-2 Step Behavior
--------
Notes
------------------------------------------------------------------------------------------------------------
The Step Behavior for the waveform and phase is always Constant (Const).
Keeps as many intra-Step parameter setting values as the number of phases in each step based
on the output phase mode.
Cannot be set using line voltage in the single-phase three-wire output and three-phase output.
The rate of crest factor/clip ratio cannot be changed though a clipped sine wave can be selected
as an output waveform in Sequence function. Set these parameters beforehand using
continuous output function.
Sequence function displays the measured value in Sequence function, which is equivalent to
that of the continuous output function. However, harmonic current measurement (see
4.4
)
cannot be displayed.
-----------------------------------------------------------------------------------------------------------------------------
Step Behavior
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...