4. Advanced Operation
PROGRAMMABLE AC/DC POWER SOURCE
166
--------
Notes
------------------------------------------------------------------------------------------------------------
When the unbalanced mode is switched to the balanced mode, the AC voltage of each phase
becomes equal to the setting value of the L1 phase. The phase setting value is the value of the
balanced mode (180 degrees for single-phase three-wire output, and 120 degrees and 240
degrees for three-phase output).
Switching between the unbalanced mode and balanced mode is possible even in the output on
state.
-----------------------------------------------------------------------------------------------------------------------------
4.16 Using as DC Power Supply
You can use this product as a DC power supply by switching the AC/DC mode to the DC mode or
the ACDC mode. For the voltage setting range, see
10.6
.
--------
Notes
------------------------------------------------------------------------------------------------------------
The polyphase system cannot be used as a DC power supply. The DC mode cannot be used.
The DC voltage (DCV) of the ACDC mode also cannot be set.
The signal sources that can be combined with the ACDC mode are INT, SYNC, EXT, and
ADD.
The signal sources that can be combined with the DC mode are INT and VCA.
-----------------------------------------------------------------------------------------------------------------------------
Operation Method
1.
Enter the ACDC mode or the DC mode. Following two methods are available.
(a)
Shortcut operation:
+
Every time you press the keys, the mode is switched to AC, ACDC, and DC in this order.
(b)
Press the [Osc] soft-key and select [1:AC/DC]. From the opened menu, select [2: ACDC] or
[3: DC].
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...