4.18 Control Using External Control Function
KP3000S
171
3.
Set the [Gain] item.
4.
Supply a DC voltage to the external signal input connector.
5.
Turn on the output.
4.18 Control Using External Control Function
You can control the output on/off and the starting/stopping of Sequence by inputting the logic signal
or the non voltage contact signal. You can also get the product state by using the logic signal. The
polarity of state output can be switched. The connector to be used is DBLC-J25SAF-10L9E (D-sub,
25-pin, M2.6 mm screw) manufactured by JAE. For the specification of I/O signals, see
10.26
, and
for the pin assignment of the CONTROL I/O connector, see Table 4-12.
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...