3.3 Basic Key Operations
KP3000S
39
3.3.7 Using Shortcut Operations (SHIFT Key)
When you press the SHIFT key, the SHIFT LED illuminates. In this state (shift state), pressing one
of the V, F, I, and any keys in the numeric keypad enables shown in Table 3-6. In this instruction
manual, pressing a key in the shift state is denoted by "
+ X."
If you press the SHIFT key once more in the shift state, the SHIFT LED is lighted off and the shift
state exits.
--------
Notes
------------------------------------------------------------------------------------------------------------
The shift state is kept until you press the SHIFT key next time. Therefore, continuous Shortcut
operations can be performed.
You do not have to hold down the SHIFT key while you press another key.
-----------------------------------------------------------------------------------------------------------------------------
Table 3-6 Shortcut Operations
Shortcut Item
Description Refer
to
+
V-LIMIT
Opens the setting window for the voltage setting
range limit.
4.1.3
+
F-LIMIT
Opens the setting window for the frequency
setting range limit.
4.1.4
+
Ipk-LIMIT
Opens the peak current limiter set window.
4.1.1
+
S-L1/L2/L3
†
Switches the target phase to be configured in
the following order: L1, L2, L3 (unbalanced
mode), All Phase, and All Line (balanced
mode).
3.4.5
,
4.15
+
M-L1/L2/L3
†
Switches the target phase of which the
measured value is displayed in the following
order: L1, L2, L3, L1-L2, L2-L3, L3-L1.
3.4.13
+
RMS/AVG/PK
†
Switches the display format of the measured
value in the following order: RMS, AVG, PK.
3.4.10
+
KEY LOCK
Enables/Disables the key lock.
4.25
+
AGC/Acal
Opens the AGC/Autocal set window.
4.12
,
4.13
+
USB-EJECT
Performs the eject operation for removing a
USB memory.
4.9
+
AC/DC
Switches the AC/DC mode in the following
order: AC, ACDC, DC.
3.4.1
+
SOURCE
Switches the signal source in the following
order: INT, VCA, SYNC, EXT, ADD.
3.4.1
+
CONTRAST
Changes to the state in which the contrast is
selected in the LCD set window.
4.27
+
LOCAL
Exits the Remote state between the devices
connected to the communication interface and
enters the Local state in which the panel
operations are accepted.
6.2
+
DISP
Switches the measured value display mode
between normal and simple.
3.4.11
+
Ipk CLR
Clears the current peak-hold value.
3.4.12
Note: If you change the item presented with † symbol using a Shortcut operations, the setting is not saved in the
System Setting Memory (see
10.24
).
Содержание KP3000S
Страница 1: ...PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL NF Corporation...
Страница 2: ......
Страница 3: ...DA00030908 004 PROGRAMMABLE AC DC POWER SOURCE KP3000S INSTRUCTION MANUAL...
Страница 4: ......
Страница 19: ...KP3000S 1 1 Outline 1 1 Overview 2 1 2 Polyphase System Configuration 2 1 3 Features 2...
Страница 22: ......
Страница 42: ......
Страница 78: ......
Страница 210: ......
Страница 211: ...KP3000S 193 5 Description of Screen and Menu 5 1 Screen Configuration 194 5 2 Menu Composition 198...
Страница 220: ......
Страница 221: ...KP3000S 203 6 Remote Control 6 1 Communication Interface 204 6 2 Remote Local State Switching 210...
Страница 233: ...KP3000S 215 8 Troubleshooting 8 1 Error Messages and Error Handling 216 8 2 When a Failure is Suspected 223...
Страница 252: ......
Страница 286: ......
Страница 288: ......
Страница 289: ......
Страница 290: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN...