DWS-SWITCH-MONO

INSTALLATION MANUAL

AC Power Disconnector and Distributor

Summary of Contents for DWS-SWITCH-MONO

Page 1: ...L DWS SWITCH MONO INSTALLATION MANUAL AC Power Disconnector and Distributor...

Page 2: ...ll notices appear on any reproductions of the documentation Electronic versions of this document may be downloaded from the Datalogic website www data logic com If you visit our website and would like...

Page 3: ...l Support iv Safety Regulations v Electrical Safety v Product Label v CE Compliance v General View vi CHAPTER 1 INTRODUCTION 1 CHAPTER 2 INSTALLATION 2 Cabinet Mounting 2 System Wiring AC Output 3 Sys...

Page 4: ...ces and Technical Support Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A reseller is acquainted with specific types of bu...

Page 5: ...c promptly adopts these updates therefore the EU declaration of conformity is a living document The EU declaration of conformity is available for competent authorities and customers through Datalogic...

Page 6: ...H MONO General View 6 1 2 4 5 7 8 3 2 1 Key Lock 5 AC Ouput Cable Compression Connectors 2 Main Switch 6 AC Line Input Terminals and Protection Earth 3 Product Data Label 7 AC Line Fuses 4 AC Input Ca...

Page 7: ...o power a system composed of four electrical loads a Datalogic PWR 480W electrical panel a Scale digital section a Datalogic PWR 2400 electrical panel and a Datalogic PWR 480B PWR 240B or PWR 120 elec...

Page 8: ...ts and bolts provided in the package 1 Mount the bracket to the cabinet 2 Mount the cabinet to the frame Figure 3 Mounting Brackets Figure 4 DWS SWITCH MONO cabinet max height IMPORTANT The cabinet mu...

Page 9: ...OUT 1 and OUT 2 Figure 5 Terminal Block for Out 1 and Out 2 The terminal block for Out 1 PWR 480W and for Out 2 Scale is highlighted in the picture above Use cables 3 X yy mm2 where yy is a value betw...

Page 10: ...Out 3 is protected by Fuse QF02 16A gG System Wiring OUT 4 Figure 7 Terminal Block for Out 4 The terminal block for Out 4 PWR 480B or PWR 240B or PWR 120 is highlighted in the picture above Use cable...

Page 11: ...power supply to the DWS SWITCH MONO use a 3 conductor cable with size of 4 mm2 Follow the procedure below to wire the AC input line 1 Connect the L line to the L pole of the bar placed on the fuses bl...

Page 12: ...DWS SWITCH MONO DWS SWITCH MONO ELECTRICAL DIAGRAM The DWS SWITCH MONO components are electrically connected as displayed in the fol lowing diagram Figure 9 DWS SWITCH MONO Electrical Diagram Drawing...

Page 13: ...V 1 50 Hz I max 28 A Icp 10kA Output 230 V 1 50 Hz I max 16 A 230 V 1 50 Hz I max 8 A 230 V 1 50 Hz I max 4 A ENVIRONMENTAL FEATURES Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 20...

Page 14: ...ght no part of this documentation may be repro duced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permissio...