keyPAD
keyPAD beePs
beePs
meAning
1 BeeP
Any key press.
3 BeePS
Valid Command.
––
1 lONG BeeP error.
..
10
..
10 BeePS
Mains Power is off
or Panel Battery is low
or A Radio Device
has sent a low battery
signal
or Telephone line Fail
has been detected.
... ... ...
Constant SlOW beeps
An AutoTime action is
due to begin.
. . .
Constant FAST beeps
An AutoTime action
will begin in
one
minute.
keyPAD DisPlAy inDiCAtors in memory moDe
keyPAD iCon
memory eVent
Zone numbers 1–8 or 1–16
Zone alarm
(no icons displayed)
Panel Disarmed
ARMeD
Panel Armed (or Area 1 Armed)
ARM2
Area 2 Armed
MAINS
Mains power failure
BATTeRy
low Battery
1
Internal Tamper alarm
2
external Tamper alarm
e 1
Panic alarm
e 2
Medical alarm
e 3
Fire alarm
lINe
Telephone line fail
RADIO, eXClUDe
Radio Key Panic alarm
RADIO, BATTeRy, ZONe
Radio Device battery low, (Device number is indicated by zone lights)
RADIO, BATTeRy, ARM
Radio Key battery low, (Radio Key number is NOT indicated)
RADIO, TAMPeR, ZONe
Radio Device tamper alarm (Device number is indicated by zone lights)
RADIO, HOMe, ZONe
Radio Supervision alarm (Device number is indicated by zone lights)
HOMe, ZONe
Wired Zone Supervision alarm (Zone number is indicated by zone lights)
DISPlAy TeST
To display all available keypad icons
press and hold the
button for at least
2 seconds. All icons will be displayed
while the
button is held down.
Display Test can be activated at any time
either in operating mode or any program
mode.
NUMBeR OF KeyPADS
Up to 3 lCD keypads can be connected
to a panel.
CABle leNGTH
The maximum allowable cable length is
100m (total cable length to all keypads).
The instructions on this page relate to
Ness Saturn and KPX keypads.
Refer to the Ness Navigator user's
manual for operating instructions specific
to the Navigator Touch Screen keypad.
keyPAD DisPlAy inDiCAtors in oPerAting moDe
keyPAD iCon
DisPlAy
oFF
on
FlAsHing
Zones
1-8 (or 1-16)
Zone is sealed.
Zone is unsealed.
Zone is in alarm.
READY TO ARM
OK
Zone/s are unsealed.
or Power fault.
or Panel is armed.
or phone line fault.
Ready to Arm
ARMED
Panel is disarmed,
or Area 1 is disarmed, if
using Areas.
Panel is armed,
or Area 1 is armed, if
using Areas.
ARMED
Area 2 is disarmed.
Area 2 is armed if
using Areas.
HOME
Home Mode is disarmed.
Panel is armed in
Home Mode.
Day Mode enabled, (see
page 20).
MEMORY
Normal.
Memory mode
selected.
New alarm/s in memory.
Normal.
Receiving a radio
signal. (If radio fitted.)
A Radio Key or other
radio device has low
battery.
TAMPER
Normal.
Internal Tamper: Double
Flash with long pause.
external Tamper: Steady
flash.
EXCLUDE
Normal.
Zone/s are excluded.
LOW
BATTERY
Normal.
The backup battery
is low.
MAINS
OFF
Normal.
Mains power is off.
PROG
Normal.
User Program Mode.
Installer Program Mode.
LINE
Normal
Dialler is on line.
Phone line fault or
failure to communicate.
10
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl