CAllbACk moDe
enables two methods of connecting by computer for remote upload/download.
no CAllbACk
– Allows remote access by computer as long as the panel’s Account
Number (P72e) is known. The panel answers on the 2nd incoming call.
WitH CAllbACk
– The panel will answer the 2nd call, verify the caller, hang up and
then make the Callback using Telephone Number 4.
PROGRAMMING SeQUeNCe:
P90e 8e
toggles the option ON and OFF
oFF: no Callback
on: Callback Mode enabled
P90e 8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Callback.
relAteD oPtions
P90e 1e enable Upload/Download.
P81e Telephone Number 4, Callback.
remote eVent rePorting
enables Remote event Reporting
PROGRAMMING SeQUeNCe:
P90e 7e
toggles the option ON and OFF
oFF: no remote Status reporting
on: remote Status reporting enabled
P90e 7e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote event Reporting.
notes
When this option is off, the
NessComms
Receive Events
function
will appear to download the event
history from the panel, however
the NessComms event display will
(correctly) be blank.
remote stAtUs AnD Arming
enables Remote Status Reporting and Arming using NeSSCOMMS™ software.
This option allows Remote Viewing of the current arming and alarm states and Remote
Keypad Operation including arming & disarming.
Requires NessComms™ V5.2 and later.
PROGRAMMING SeQUeNCe:
P90e 6e
toggles the option ON and OFF
oFF: no remote Status reporting
on: remote Status reporting enabled
P90e 6e
Available in D8x/D16x V5.6 and later.
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote Status Reporting.
remote AUx Control
enables the remote turn ON/OFF of the AUX1, 2, 3 and 4 outputs using a standard
DTMF telephone or mobile phone.
PROGRAMMING SeQUeNCe:
P90e 5e
toggles the option ON and OFF
oFF: no remote auX control
on: remote auX control enabled
P90e 5e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote AUX control.
notes
This option must be on to globally
enable remote control of the AUX
outputs. See the options for AUX1-4 to
individually enable each AUX output for
remote control.
relAteD oPtions
P141e 5e Telephone control AUX1
P142e 5e Telephone control AUX2
P143e 5e Telephone control AUX3
P144e 5e Telephone control AUX4
remote DisArming
Allows the control panel to be disarmed remotely by telephone, using a standard
DTMF telephone or mobile phone.
PROGRAMMING SeQUeNCe:
P90e 4e
toggles the option ON and OFF
oFF: no remote Disarming
on: remote Disarming enabled
P90e 4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No Remote Disarming.
51
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
Содержание D16xD
Страница 94: ...NOTES ...
Страница 96: ......