AUDible VoiCe monitoring - enHAnCeD
D8x/D16x version 8.0 and later has exhanced audible monitoring features using an
onboard library of voice messages to deliver clear and concise spoken word alarm
messages to the recipient's mobile phone or landline.
Audible messages are detailed and interactive, with spoken word messages clearly
stating the alarm condition being reported. The user can then acknowledge the alarm
and hang up or enter a remote control menu which gives options to arm and disarm
the system, control auxiliary outputs and even exclude zones - all over the phone.
AlARM MeSSAGe TRANSMISSION
Alarm reports are sent to the Primary (P70e) and Secondary (P71e) telephone
numbers or only to the Follow Me phone number (P00e) if programmed.
AlARM MeSSAGe FORMAT
The alarm message starts with the introduction:
This is a security system message. To start the report press 1.
The recipient must press 1 on their phone. If not, the message repeats.
[System Name] security system reports the following
System Name is programmed by option p198E
[Alarm or Message] (See the Voice Messages table)
Wait to hear the report again, or to continue, press 1.
press 1 on your phone. More alarm reports, if any, are heard.
Once all alarms have been acknowledged.
end of messages. To control the security system press 2 then, after the tone press
2 again. To acknowledge and end, press STAR then press HASH and then hang up the
phone.
Press STAR then HASH to hang up.
Press 2 then 2 to continue to the telephone remote control menu. See page 85.
This section applies to
V8.0 and later
AUDible monitoring
Note that the operation of Audible
Monitoring has changed over several
revisions of D8/D16 control panels
D8/D16 ReVISION
AUDIBle MONITORING TyPe
Prior to V5.6
Audible beeps
V5.6 – V7.8
Audible beeps and spoken word “Alarm”
V8.0 and later
extensive library of spoken word messages for audible
monitoring and spoken prompts for remote phone operation
CentrAl stAtion monitoring
The Ness D8x and D16x control panels have an on-board digital dialler which can send
detailed alarm messages to a central monitoring station.
The digital messages can include information about the zone/s which caused the
alarm, tamper alarms, low battery or mains failure reports, and it can also (by user
number) identify the users who arm and disarm the system.
Central station monitoring is highly recommended and is the most effective method of
monitoring your alarm system.
Installers are welcome to contact Ness for further information about monitoring.
MONITORED
PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE
MONITORING
STATION
83
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Содержание D16xD
Страница 94: ...NOTES ...
Страница 96: ......